Geometry of the intervertebral volume and vertebral endplates of the human spine EB Van der Houwen, P Baron, AG Veldhuizen, JGM Burgerhof, ... Annals of biomedical engineering 38, 33-40, 2010 | 111 | 2010 |
Diffusion‐weighted imaging of normal fibroglandular breast tissue: influence of microperfusion and fat suppression technique on the apparent diffusion coefficient P Baron, MD Dorrius, P Kappert, M Oudkerk, PE Sijens NMR in Biomedicine: An International Journal Devoted to the Development and …, 2010 | 110 | 2010 |
In vivo T2‐based MR thermometry in adipose tissue layers for high‐intensity focused ultrasound near‐field monitoring P Baron, M Ries, R Deckers, M De Greef, J Tanttu, M Köhler, ... Magnetic resonance in medicine 72 (4), 1057-1064, 2014 | 88 | 2014 |
Effects of microperfusion in hepatic diffusion weighted imaging H Dijkstra, P Baron, P Kappert, M Oudkerk, PE Sijens European radiology 22, 891-899, 2012 | 66 | 2012 |
T1 and T2 temperature dependence of female human breast adipose tissue at 1.5 T: groundwork for monitoring thermal therapies in the breast P Baron, R Deckers, FM Knuttel, LW Bartels NMR in Biomedicine 28 (11), 1463-1470, 2015 | 43 | 2015 |
Influence of water and fat heterogeneity on fat‐referenced MR thermometry P Baron, R Deckers, JG Bouwman, CJG Bakker, M de Greef, ... Magnetic Resonance in Medicine 75 (3), 1187-1197, 2016 | 37 | 2016 |
Correction of proton resonance frequency shift MR‐thermometry errors caused by heat‐induced magnetic susceptibility changes during high intensity focused ultrasound ablations … P Baron, R Deckers, M de Greef, LG Merckel, CJG Bakker, JG Bouwman, ... Magnetic Resonance in Medicine 72 (6), 1580-1589, 2014 | 37 | 2014 |
Quantitative multivoxel proton chemical shift imaging of the breast PE Sijens, MD Dorrius, P Kappert, P Baron, RM Pijnappel, M Oudkerk Magnetic resonance imaging 28 (3), 314-319, 2010 | 37 | 2010 |
Correction of motion‐induced susceptibility artifacts and B0 drift during proton resonance frequency shift‐based MR thermometry in the pelvis with background field … M Wu, HT Mulder, P Baron, E Coello, MI Menzel, GC van Rhoon, A Haase Magnetic Resonance in Medicine 84 (5), 2495-2511, 2020 | 30 | 2020 |
Spatial distribution of oil depots monitored in human muscle using MRI RW Kalicharan, P Baron, C Oussoren, LW Bartels, H Vromans International journal of pharmaceutics 505 (1-2), 52-60, 2016 | 22 | 2016 |
The effects of magnetic resonance imaging-guided high-intensity focused ultrasound ablation on human cadaver breast tissue LG Merckel, R Deckers, P Baron, RLAW Bleys, PJ Van Diest, ... European Journal of Pharmacology 717 (1-3), 21-30, 2013 | 10 | 2013 |
Comparison of conventional and higher-resolution reduced-FOV diffusion-weighted imaging of breast tissue P Baron, M Wielema, H Dijkstra, JH Potze, MD Dorrius, PE Sijens Magnetic Resonance Materials in Physics, Biology and Medicine 36 (4), 613-619, 2023 | 4 | 2023 |
Measurement of the T1 and T2 temperature dependence of human breast adipose tissue P Baron, R Deckers, SM Sprinkhuizen, LG Merckel, RL Bleys, CJ Bakker, ... International Society Magnetic Resonance in Medicine, 2011 | 4 | 2011 |
In vivo validation of T2-based MR thermometry in adipose tissue layers for HIFU near-field monitoring P Baron, MG Ries, M de Greef, R Deckers, M Kohler, J Tanttu, ... International Society Magnetic Resonance in Medicine}}, 2014 | 3 | 2014 |
Accuracy of ADC measurements with an ultrashort echo time diffusion weighted stimulated echo 3D Cones sequence (DW-STEAM 3D Cones UTE) P Baron, DHJ Poot, PA Wielopolski, EHG Oei, A Juan Proc Intl Soc Mag Reson Med, 3452, 2017 | 2 | 2017 |
Influence of reference tube location on the measured sodium concentrations in calf muscles using a birdcage coil at 3T P Baron, JH Potze, PE Sijens Magnetic Resonance in Medicine 90 (2), 624-632, 2023 | 1 | 2023 |
Effect of the transceive phase on MR thermometry in acqueous mediums G Salim, P Baron, D Poot, JAH Tamames, T Drizdal, MM Paulides, S Klein Proceedings of the 25th Annual Meeting of ISMRM, Honolulu, HI, 5422, 2017 | 1 | 2017 |
Influence of Magnetic Susceptibility on Absolute Temperature as Measured Directly from the Water/Fat Frequency Shift P Baron, M De Greef, R Deckers, CJG Bakker, JG Bouwman, LW Bartels Proceedings of the 23rd Annual Meeting of ISMRM, Milan, Italy, 3678, 2014 | 1 | 2014 |
MR thermometry in fat-containing tissues for MR-guided High Intensity Focused Ultrasound therapy P Baron Utrecht University, 2015 | | 2015 |
Correction of errors in PRFS Thermometry due to heat induced susceptibility changes of fat P Baron, R Deckers, SM Sprinkhuizen, CJG Bakker, LW Bartels International Society Magnetic Resonance in Medicine}}, 1774 | | 1774 |